BALANCED belting is designated by numberals
indicating, respectively, number of "turn" or "loops"
per foot of length, and gauge of wire. When the gauge of tthe spiral
differs form that of the crimped connector, the third numeral indicates
the gauge of the crimped connector and the last numeral the gauge of
the spiral.
|
Mesh Designation
|
Approx. Mesh
|
Dia.of Wire in.
|
Cross Sec.Area sq.in/ft
|
tMax. Working Tension
Ib/ft.
|
Weight Ib./sq.ft
|
|
B-6-9-6
|
2"
|
.192 |
.347
|
440
|
2.85
|
| B-6-9-10 |
2"
|
.135 |
.172
|
160
|
1.50
|
| B-8-9-9 |
11/2"
|
.148 |
.276
|
360
|
1.81
|
| B-12-11-6 |
1"
|
.192 |
.695
|
1780
|
5.00
|
| B-12-10-9 |
1"
|
.148 |
.415
|
820
|
2.51
|
| B-12-10-12 |
1"
|
.105 |
.210
|
290
|
1.25
|
| B-18-18-9 |
3/4"
|
.148 |
.622
|
1850
|
4.75
|
| B-18-17-10 |
3/4"
|
.135 |
.515
|
1400
|
3.69
|
| B-18-16-11 |
3/4"
|
.120 |
.411
|
990
|
2.75
|
| B-18-16-10-12 |
3/4"
|
.135-.105 |
.315
|
895
|
2.50
|
| B-18-16-12 |
3/4"
|
.105 |
.315
|
660
|
2.00
|
| B-18-5-14 |
3/4"
|
.080 |
.181
|
295
|
1.00
|
| B-18-15-14-16 |
3/4"
|
.080-.063 |
.110
|
145
|
1.00
|
| B-24-23-10 |
1/2"
|
.135 |
.687
|
2480
|
5.50
|
| B-24-25-10-12 |
1/2"
|
.135-.105 |
.420
|
1585
|
4.00
|
| B-24-22-12 |
1/2"
|
.105 |
.420
|
1175
|
2.95
|
| B-24-27-12 |
1/2"
|
.105 |
.420
|
1175
|
3.50
|
| B-24-21-14 |
1/2"
|
.080 |
.241
|
510
|
1.50
|
| B-24-21-14-16 |
1/2"
|
.080-.063 |
.147
|
260
|
1.00
|
| B-30-20-12 |
3/8"
|
.105 |
.525
|
1830
|
3.63
|
| B-30-24-12 |
3/8"
|
.105 |
.525
|
1830
|
3.44
|
| B-30-30-11-12 |
3/8"
|
.120-.105 |
.525
|
2140
|
4.56
|
| B-30-28-14 |
3/8"
|
.080 |
.302
|
850
|
2.00
|
|
|
Mesh Designation
|
Approx. Mesh
|
Dia.of Wire in.
|
Cross Sec.Area sq.in/ft
|
tMax. Working Tension
Ib/ft
|
Weight Ib./sq.ft
|
| B-60-24-14 |
5
|
.080
|
.603
|
2410
|
3.94
|
| B-60-38-14 |
5
|
.080
|
.603
|
2410
|
4.13
|
| B-60-38-15 |
5
|
.072
|
.489
|
1760
|
3.25
|
| B-60-24-14-16 |
5
|
.080-.063 |
.368
|
1288
|
2.31
|
| B-60-50-16 |
5
|
.063
|
.368
|
1150
|
2.63
|
| B-60-55-16 |
5
|
.063
|
.368
|
1150
|
3.00
|
| B-60-31-18 |
5
|
.047
|
.213
|
405
|
1.31
|
| B-60-47-18 |
5
|
.047
|
.213
|
405
|
1.38
|
| B-60-54-18 |
5
|
.047
|
.213
|
405
|
1.50
|
| B-60-60-18 |
5
|
.047
|
.213
|
405
|
1.69
|
| B-72-24-16 |
6
|
.063
|
.442
|
1380
|
2.35
|
| B-72-56-16 |
6
|
.063
|
.442
|
1380
|
3.50
|
| B-72-56-18 |
6
|
.047
|
.255
|
585
|
1.72
|
| B-72-60-18 |
6
|
.047
|
.255
|
585
|
1.75
|
| B-72-68-18 |
6
|
.047
|
.255
|
585
|
2.19
|
| B-72-72-20 |
6
|
.035
|
.137
|
160
|
1.10
|
| B-84-82-1! |
7
|
.047
|
.298
|
715
|
2.50
|
| B-84-84-20 |
7
|
.035
|
.160
|
220
|
1.10
|
| B-144-105-20-22 |
12
|
.035-.028 |
.185
|
295
|
1.31
|
*Units per foot of belt
width
For steel and stainless
steel belts operating at temperatures to 600'F(316¢ªC). maxium For special
conditions, hogher temperatures, and explanation of "Maximum Working